Specifications
Certificate: SGS & REACH
Shape: Sphere
Bulk Density: G/ml ≥ 0.85
Size: 1.6-2.5mm
Dew Point: ℃ ≤ -73
Package Moisture: WT ≤ 1.5%
Compressive Strength: 80N
Static Water Adsorption: WT ≥ 16.5%-21%
Adsorbent Variety: Molecular Sieve
Usage: Paper Chemicals,Plastic Auxiliary Agents,Petroleum Additives,Rubber Auxiliary Agents,Coating Auxiliary Agents
Attrition Rate: WT < 0.1%
Classification: Chemical Auxiliary Agent
CAS No.: 70955-01-0
High Light:

Refrigerant Desiccant Molecular Sieve Beads

,

Avoid Freezing Molecular Sieve Desiccant

,

Molecular Sieve Refrigerant Chemicals

Basic Infomation
Place of Origin: Shaanxi,China
Brand Name: Xi'an Lvneng
Certification: ISO9001:2015
Model Number: Refrigerant Desiccant
Payment & Shipping Terms
Packaging Details: 1. 25KG/Carton Drum, 2. 25KG/Carton Box, 3. 150KG/Sealed Iron Drum
Delivery Time: 3-15 work days
Payment Terms: T/T, L/C, Western Union
Supply Ability: 100 Tons/ per Month
Product Description

Molecular Sieve XH Refrigerant Desiccant Adsorbent For Avoid Freezing Capillary Expansion Valve


Product Description of Refrigerant Desiccant

The compressor sucks in the low-temperature and low-pressure freon gas from the evaporator and compresses it into high-temperature and high-pressure freon gas, and then flows through the thermal expansion valve (capillary), throttling into a low-temperature and low-pressure freon vapor-liquid two-phase object, and then low-temperature and low-pressure freon gas. The freon liquid absorbs the heat from the indoor air in the evaporator and becomes a low temperature and low pressure freon gas, and the low temperature and low pressure freon gas is sucked by the compressor.

 

After the indoor air passes through the evaporator, heat is released and the air temperature drops. In this way, the compression----condensation----throttling----evaporation is repeatedly cycled, and the refrigerant continuously takes away the heat of the indoor air, thereby reducing the temperature.

 

Moisture is generated during this process, and long-term use can corrode accessories and damage system performance. Using Lvneng molecular sieve XH series products will avoid this problem.

  • XH-5 used commercially for dehydration and drying of refrigerants R12, R22.
  • XH-7 used for dehydration and drying of new refrigerants R-134a in household and commercial refrigerators, iceboxes and air conditioners. It is also used for specialized refrigerants such as butane in "green" refrigerators.
  • XH-9 used commercially in drying refrigerants in air conditioners, iceboxes and refrigerators in cars, station wagons, refrigerating trucks, trains and ships.(Excludes refrigerant mixtures containing difluoromethane)
  • XH-11 available in bead for dehydration and drying of refrigerants R407c, R-410A. or Medium high temperature refrigerant.

 
Technical Specification of Refrigerant Desiccant

Items Unit XH-5 XH-7 XH-9 XH-11
Diameter mm 1.6-2.5 1.6-2.5 1.6-2.5 1.6-2.5
Equilibrium Water Capacity (25°c) wt% ≥ 21 17.5 17 16.5
Loss on Ignition(LOI)@960℃ (wt%) wt% MAX. 1.2% MAX. 1.2% MAX. 1.2% MAX. 1.2%
Bulk Density g/ml ≥ 0.85 0.85 0.85 0.85
Crush Strength N ≥ 80 80 80 80
Attrition Rate Dry wt % ≤ 0.1 0.1 0.1 0.1
  Humidity wt % ≤ 2.0 2.0 2.0 2.0
Package Moisture wt % ≤ 1.5 1.5 1.5 1.5

This is just basic information about Refrigeration Drying Molecular Sieve

 
Display of Refrigerant Desiccant
Molecular Sieve Refrigerant Desiccant Adsorbent For Avoid Freezing Capillary Expansion 0
 
Application of Refrigerant Desiccant

Molecular Sieve Refrigerant Desiccant Adsorbent For Avoid Freezing Capillary Expansion 1
 
Package of Refrigerant Desiccant
Molecular Sieve Refrigerant Desiccant Adsorbent For Avoid Freezing Capillary Expansion 2
 
Factory View of Refrigerant Desiccant
Molecular Sieve Refrigerant Desiccant Adsorbent For Avoid Freezing Capillary Expansion 3
 
Attention of Refrigerant Desiccant

  • The product cannot be exposed in the open air & should be stored in dry condition with air-proof bag.
  • It should be regenerated after a certain period of adsorption. The appropriate regenerated temperature would be better below 350°C.

 
FAQ of Refrigerant Desiccant

Q: Could we send a free sample for reference?
A: Yes, of course.

Q: What about the price and MOQ?
A: We promise a competitive price with top quality, & accept both mass and small quantity order.

Q: What is the lead time?
A: Within 15 days after received payment.

Q: Payment term?
A: 100% TT in advance. or 30% TT deposit & balance before shipment.

Q: How to solve problems after sales?
A: Take photos of the problems. After confirmed, we will make a satisfying solution for you within 3 days.

For more information please contact us. It's our pleasure to serve you.

Recommended Products
Get in touch with us
Fax : 86-029-83990889
Characters Remaining(20/3000)