Send Message

Low Wear Refrigerant Desiccant Zeolite Molecular Sieve For Car Wagons XH - 9

10 Kilograms
MOQ
Negotiable
Price
Low Wear Refrigerant Desiccant Zeolite Molecular Sieve For Car Wagons  XH - 9
Features Gallery Product Description Request A Quote
Features
Specifications
Certificate: SGS & REACH
Shape: Sphere
Bulk Density: G/ml ≥ 0.85
Size: 1.6-2.5mm
Dew Point: ℃ ≤ -73
Package Moisture: WT ≤ 1.5%
Compressive Strength: 80N
Static Water Adsorption: WT ≥ 16.5%-21%
Adsorbent Variety: Molecular Sieve
Usage: Paper Chemicals,Plastic Auxiliary Agents,Petroleum Additives,Rubber Auxiliary Agents,Coating Auxiliary Agents
Attrition Rate: WT < 0.1%
Classification: Chemical Auxiliary Agent
CAS No.: 70955-01-0
High Light:

Refrigerant Zeolite Molecular Sieve

,

Zeolite Molecular Sieve Low Wear

,

Car Wagons Molecular Sieve Desiccant

Basic Infomation
Place of Origin: Shaanxi,China
Brand Name: Xi'an Lvneng
Certification: ISO9001:2015
Model Number: Refrigerant Desiccant
Payment & Shipping Terms
Packaging Details: 1. 25KG/Carton Drum, 2. 25KG/Carton Box, 3. 150KG/Sealed Iron Drum
Delivery Time: 3-15 work days
Payment Terms: T/T, L/C, Western Union
Supply Ability: 100 Tons/ per Month
Product Description

Good Compatibility Strength Low Wear XH-9 Zeolite Molecular Sieve Refrigerant Desiccant For Car Wagons


Product Description of Refrigerant Desiccant

The function of desiccant in automobile air conditioner is to absorb moisture in the refrigeration system. Special attention should be paid to high strength and low wear when using desiccant in automobile air conditioner refrigeration system.

 

The desiccant should also have better compatibility with the refrigerant. High-quality molecular sieves have the properties of high strength, low abrasion and good water absorption. Therefore, molecular sieves are mainly used as desiccants in automobile air conditioners at present.

The XH series of desiccants set the standard for refrigerant drying in automotive and stationary refrigeration systems with excellent cost-efficiency and high operating reliability.


We know that during refrigeration, uncontrolled system moisture can freeze capillaries and expansion valves; during manufacture or after prolonged use, water can enter the system through hoses, fittings, and other components, and because of hydrolysis The process produces acids that corrode metal parts, and deposits cause blockages in expansion devices.

 

Lvneng molecular sieve desiccant can avoid system failure by controlling this pollution. We also serve your changing needs with the following objectives:

  • XH-5 used commercially for dehydration and drying of refrigerants R12, R22.
  • XH-7 used for dehydration and drying of new refrigerants R-134a in household and commercial refrigerators, iceboxes and air conditioners. It is also used for specialized refrigerants such as butane in "green" refrigerators.
  • XH-9 used commercially in drying refrigerants in air conditioners, iceboxes and refrigerators in cars, station wagons, refrigerating trucks, trains and ships.(Excludes refrigerant mixtures containing difluoromethane)
  • XH-11 available in bead for dehydration and drying of refrigerants R407c, R-410A. or Medium high temperature refrigerant.

 
Technical Specification of Refrigerant Desiccant

Items Unit XH-5 XH-7 XH-9 XH-11
Diameter mm 1.6-2.5 1.6-2.5 1.6-2.5 1.6-2.5
Equilibrium Water Capacity (25°c) wt% ≥ 21 17.5 17 16.5
Loss on Ignition(LOI)@960℃ (wt%) wt% MAX. 1.2% MAX. 1.2% MAX. 1.2% MAX. 1.2%
Bulk Density g/ml ≥ 0.85 0.85 0.85 0.85
Crush Strength N ≥ 80 80 80 80
Attrition Rate Dry wt % ≤ 0.1 0.1 0.1 0.1
  Humidity wt % ≤ 2.0 2.0 2.0 2.0
Package Moisture wt % ≤ 1.5 1.5 1.5 1.5

This is just basic information about Refrigeration Drying Molecular Sieve

 
Display of Refrigerant Desiccant
Low Wear Refrigerant Desiccant Zeolite Molecular Sieve For Car Wagons  XH - 9 0
 
Application of Refrigerant Desiccant

Low Wear Refrigerant Desiccant Zeolite Molecular Sieve For Car Wagons  XH - 9 1
 
Package of Refrigerant Desiccant
Low Wear Refrigerant Desiccant Zeolite Molecular Sieve For Car Wagons  XH - 9 2
 
Factory View of Refrigerant Desiccant
Low Wear Refrigerant Desiccant Zeolite Molecular Sieve For Car Wagons  XH - 9 3
 
Attention of Refrigerant Desiccant

  • The product cannot be exposed in the open air & should be stored in dry condition with air-proof bag.
  • It should be regenerated after a certain period of adsorption. The appropriate regenerated temperature would be better below 350°C.

 
FAQ of Refrigerant Desiccant

Q: Could we send a free sample for reference?
A: Yes, of course.

Q: What about the price and MOQ?
A: We promise a competitive price with top quality, & accept both mass and small quantity order.

Q: What is the lead time?
A: Within 15 days after received payment.

Q: Payment term?
A: 100% TT in advance. or 30% TT deposit & balance before shipment.

Q: How to solve problems after sales?
A: Take photos of the problems. After confirmed, we will make a satisfying solution for you within 3 days.

For more information please contact us. It's our pleasure to serve you.

Recommended Products
Get in touch with us
Fax : 86-029-83990889
Characters Remaining(20/3000)