Send Message

Circulating Refrigerant Desiccant Zeolite Molecular Sieve For Deeply Remove Moisture

10 Kilograms
MOQ
Negotiable
Price
Circulating Refrigerant Desiccant Zeolite Molecular Sieve For Deeply Remove Moisture
Features Gallery Product Description Request A Quote
Features
Specifications
Certificate: SGS & REACH
Shape: Sphere
Bulk Density: G/ml ≥ 0.85
Size: 1.6-2.5mm
Dew Point: ℃ ≤ -73
Package Moisture: WT ≤ 1.5%
Compressive Strength: 80N
Static Water Adsorption: WT ≥ 16.5%-21%
Adsorbent Variety: Molecular Sieve
Usage: Paper Chemicals,Plastic Auxiliary Agents,Petroleum Additives,Rubber Auxiliary Agents,Coating Auxiliary Agents
Attrition Rate: WT < 0.1%
Classification: Chemical Auxiliary Agent
CAS No.: 70955-01-0
High Light:

Remove Moisture Refrigerant Desiccant

,

Circulating Refrigerant Zeolite Molecular Sieve

,

Chemical Molecular Sieve Beads

Basic Infomation
Place of Origin: Shaanxi,China
Brand Name: Xi'an Lvneng
Certification: ISO9001:2015
Model Number: Refrigerant Desiccant
Payment & Shipping Terms
Packaging Details: 1. 25KG/Carton Drum, 2. 25KG/Carton Box, 3. 150KG/Sealed Iron Drum
Delivery Time: 3-15 work days
Payment Terms: T/T, L/C, Western Union
Supply Ability: 100 Tons/ per Month
Product Description

Refrigerant Desiccant XH Zeolite Molecular Sieve For Deeply Remove Moisture From Circulating Refrigerant


Product Description of Refrigerant Desiccant

Molecular sieves for XH series refrigerants (XH-5, XH-9, etc.: generally small size balls 1.6~2.5mm, 2~3mm) are mainly used for drying and dehydration of various refrigerants. It is suitable for car air conditioners, household air conditioners, freezers, refrigerators, etc. It is also suitable for drying and dehydration of butane and new refrigerant R-134a in green refrigerators. XH series has higher requirements on compressive strength, the minimum can not be less than 25N/piece, and the average is greater than 45N/piece. The bulk specific gravity is 0.85~0.90g/ml. In addition, the compatibility test with the refrigerant must be carried out.

 

Product features: The company's special molecular sieves for the refrigeration industry are widely used by domestic and foreign customers. They not only have good adsorption capacity, but also greatly improve their compressive strength, reduce wear, and better withstand high pressure and pressure in the system. Vibration and friction, while improving the compatibility of molecular sieves with refrigerants in the system environment.

  • XH-5 used commercially for dehydration and drying of refrigerants R12, R22.
  • XH-7 used for dehydration and drying of new refrigerants R-134a in household and commercial refrigerators, iceboxes and air conditioners. It is also used for specialized refrigerants such as butane in "green" refrigerators.
  • XH-9 used commercially in drying refrigerants in air conditioners, iceboxes and refrigerators in cars, station wagons, refrigerating trucks, trains and ships.(Excludes refrigerant mixtures containing difluoromethane)
  • XH-11 available in bead for dehydration and drying of refrigerants R407c, R-410A. or Medium high temperature refrigerant.

 
Technical Specification of Refrigerant Desiccant

Items Unit XH-5 XH-7 XH-9 XH-11
Diameter mm 1.6-2.5 1.6-2.5 1.6-2.5 1.6-2.5
Equilibrium Water Capacity (25°c) wt% ≥ 21 17.5 17 16.5
Loss on Ignition(LOI)@960℃ (wt%) wt% MAX. 1.2% MAX. 1.2% MAX. 1.2% MAX. 1.2%
Bulk Density g/ml ≥ 0.85 0.85 0.85 0.85
Crush Strength N ≥ 80 80 80 80
Attrition Rate Dry wt % ≤ 0.1 0.1 0.1 0.1
  Humidity wt % ≤ 2.0 2.0 2.0 2.0
Package Moisture wt % ≤ 1.5 1.5 1.5 1.5

This is just basic information about Refrigeration Drying Molecular Sieve

 
Display of Refrigerant Desiccant
Circulating Refrigerant Desiccant Zeolite Molecular Sieve For Deeply Remove Moisture 0
 
Application of Refrigerant Desiccant
Circulating Refrigerant Desiccant Zeolite Molecular Sieve For Deeply Remove Moisture 1
 
Package of Refrigerant Desiccant
Circulating Refrigerant Desiccant Zeolite Molecular Sieve For Deeply Remove Moisture 2
 
Factory View of Refrigerant Desiccant
Circulating Refrigerant Desiccant Zeolite Molecular Sieve For Deeply Remove Moisture 3
 
Attention of Refrigerant Desiccant

  • The product cannot be exposed in the open air & should be stored in dry condition with air-proof bag.
  • It should be regenerated after a certain period of adsorption. The appropriate regenerated temperature would be better below 350°C.

 
FAQ of Refrigerant Desiccant

Q: Could we send a free sample for reference?
A: Yes, of course.

Q: What about the price and MOQ?
A: We promise a competitive price with top quality, & accept both mass and small quantity order.

Q: What is the lead time?
A: Within 15 days after received payment.

Q: Payment term?
A: 100% TT in advance. or 30% TT deposit & balance before shipment.

Q: How to solve problems after sales?
A: Take photos of the problems. After confirmed, we will make a satisfying solution for you within 3 days.

For more information please contact us. It's our pleasure to serve you.

Recommended Products
Get in touch with us
Fax : 86-029-83990889
Characters Remaining(20/3000)